Silast D2 ETI

Silicone paste Silast D-2 ETI20 is a two-component composition. It is hardened (cured) at room temperature/room temperature vulcanizing (RTV).


Special features

  • fast and non-shrink cure at room temperature/room temperature vulcanization (RTV)
  • high tear strength
  • resistance to casting resin
  • long service life of the molds                                                  

 

Application

RTV two-component silicone rubbers Silast D-2 ETI20 is sealant with a wide range of applications – protection of electronic components and assemblies against thermal shock (until 200 °C), vibration, moisture, ozone, dust and chemical compositions.

 


Typical properties

 

Physical condition

Homogenized, easily pourable, liquid viscosity

 

Colour

White or grey

 

Density at
20 °С, g.cm-3


1.20±0.10

 


Hardness Shor A

Pot life at 20±2 °С, min    

Оptimal working time at 20±2 °С, min   

Vulcanazing time at 20±2 °С, h

Tensile strenght, МРа

Elongation, %


45÷55

                            60÷180


45÷60


 

24

1.5÷3.5

  

150÷400

 

 


Dielectric strength at 20 °С, kV


Volume Resistivity at 20 °С
(~300
V), Ω.cm


Specific Resistivity at  20 °С
(~300
V), Ω


36 (Ø25 mm thick);
38 (Ø75 mm
thick);



5,6.1014÷1,1.1015

 


1,2.1011÷8.1011

 

 

Processing

 

Component 1 (silicone paste Silast D-2 ETI20) is mixed with component 2 (cured K168) in a ratio 100:5 parts by weight at room temperature. Components 1 and 2 may only be used together if they have the same batch number.
 

 

Storage
 

The Best use before end date of each batch is shown on the product label. Storage beyond the date specified on the label does not necessarily mean that the product is no longer usable. In this case however, the properties required for the intended use must be checked for quality assurance reasons.

 

Safety notes

 

The components of the addition-curing grade Silast D-2 ETI20 contain only constituents that over many years have proved to be neither toxic nor aggressive, but still they are not recommended for use in the food and medical industries. 

Special handling precautions are therefore not required, i.e., only the general industrial hygiene regulations apply.